Information
My
name is Mr. Jakrapong
Zaelee
Nicknaem : Num
SEX : Male Age: 26 years old
Date of birth :
11/19/1987
Status : Single
Blood group : B
National : Thai
Race : Thai
Region : Budhist
Status for military : Army
Place of birth : 26/1-2
M.2 T.Numpong Numpong Khonkaen city 40310
Present Address : 71/44 M.9 T. Tungsukla
Sriracha Chonburi city 20230
Tel: 081-0486049 , 043-373282
Blogger :
jakrapongzaelee-num.blogspot.com
Facebook : jakrapong zaelee
Twitter : jakrapong2
Education
High school : at Numpongpathanasuksa
Rachamungkalapisek when 2002
Valcational : at Numpong Technical
Collage Major electornician when 2005 GPA. 3.14
High Valcational : at Khonkaen Technical
Collage Major Industrial electronic when 2007 GPA. 2.90
Bachelor Degree : Bachelro of scince Major Electrical
engineering at Rajabhat Rajanagarindha University when 2012 GPA. 3.15
Experience
Ever working : at Krajokthai Asahi Company Limited Chonburi from 30/1/2551
to 16/6/2554 position Electrician work done
-Service Utility system
.
-Service Chemical system
, N2 plant , Power house , 115 kv substation , H2 plant , Water plant , BOILER
-Service Substation and
device in substation about Switch gear , Protective relay.
-Service DCS system.
-Service Furnace ,
Burnur .
-Service Switch gear Low
voltage label Maiden.
-Service Switch gear
High voltage label ABB.
-Service Transformer , Diesel Generator 1 MW , Battery , Charger ,
UPS ,
-Install
electrical equipment on the factory.
Present working : at Blue stack company limited is
Subcontractor for ESSO Sriracha Refinery position Technician work done
-Service Utility system of
ESSO Sriracha Refinery .
-Service Chemical system
, Power house , 115 kv substation , 22 kv EGAT , Water plant , RO , BOILER.
-Service Gas turbine
generator 25MW , 12 MW label ABB.
-Service Substation and
device in substation about
- 115 kv substation
- 22 kv EGAT
- On load tap change (OLTC)
- Power Transformer
- Disconnecting switch (DS)
- Current transformer
- SF6 circuit breaker
- Load break switch (LBS)
- Vacuum circuit breaker (VCB)
- Battery
- Charger system
- UPS
-Service Motor , MCC ,
Accel/Reaccel system , PLC load shed system.
-Service Protective
relay about
-Instantaneous over current relay.
-Time over current relay.
- Under current relay.
- Ground over current relay.
- Over voltage relay.
- Under voltage relay.
- Differential relay.
- Distance relay.
- Auto reclose relay.
- Sync. Relay.
- Motor protection relay.
- Thermal relay.
-Service Switch gear Low
voltage label
- AEG
- S&I
-Service Switch gear
High voltage label
- GEC
- ABB
- SACE
- WHIPP&BOURN
-Service Petroleum and Paraxyrean .
Program computer
- Microsoft office ,Word
, Excel , Power point
- Auto cad
- Proteus
- Google sketch up